VELLEMAN CATALOG
-
SWITCHING POWER SUPPLY - SINGLE OUTPUT - 100 W - 36 V
Код товара:
ELG-100-36A-3Y
Описание:
Features:- constant voltage + constant current mode output
- metal housing design
- : built-in active PFC function
- class 2 power unit
- no load / standby power consumption <0.5W
- IP65 rating for indoor or outdoor installations
- function options: output adjustable via potentiometer; 3in1 dimming(dim-to-off); smart timer dimming; DALI
- typical lifetime > 50.000 hours
- 5 years warranty
- for professional use only
- This device must be installed by a qualified person.
- output:
- DC voltage: 36 V
- constant current region : 18 V - 36 V
- rated current: 2.66 A
- rated power: 95.76 W (200 VAC to 305 VAC), 70 W (100 VAC to 180 VAC)
- ripple & noise (max.): 250 mVp-p
- voltage adj. range: 32.4 V - 39.6 V
- current adj. range: 1.33 A - 2.66 A
- voltage tolerance: ± 2.5 %
- line regulation: ± 0.5 %
- load regulation: ± 1.0 %
- setup, rise time : 1000 ms, 80 ms / 115 VAC, 500 ms, 100ms / 230 VAC
- hold-up time (typ.): 15 ms / 115 VAC, 10 ms / 230 VAC
- input:
- voltage range: 100-305 VAC 142-431 VDC
- frequency range: 47 to 63 Hz
- power factor: PF >/= 0.97 / 115 VAC, PF >/= 0.95 / 230 VAC, PF >/= 0.92 / 227 VAC at full load
- total harmonic distortion: THD < 20% (@load >/= 50% / 115 VAC, @load >/= 60% / 230 VAC; @load >/= 75% / 277 VAC)
- efficiency (typ.): 89 %
- AC current: 1.1 A / 115 VAC, 0.6 A / 230 VAC, 0.5 A / 227 VAC
- inrush current (typ.): cold start 60 A / 230 VAC
- max. PSUs on 16A circuit breaker: 3 units (circuit breaker type B) / 6 units (circuit breaker type C) at 230 VAC
- leakage current: < 0.75 mA / 277 VAC
- no load / standby power consumption: < 0.5 W
- wiring type: 3-wire input
- protection:
- overcurrent :
- 95 to 108 %
- protection type: constant current limiting, recovers automatically after fault condition is removed
- short-circuit: hiccup mode, recovers automatically after fault condition is removed
- overvoltage:
- 41 V - 48 V
- protection type: shut down output voltage, re-power on to recover
- overtemperature: shut down output voltage, re-power on to recover
- overcurrent :
- environment:
- working temperature: -40 °C to +90 °C
- max. case temperature: +90 °C
- working humidity: 20 - 95% RH non-condensing
- storage temperature, humidity: -40 °C - +80 °C, 10 - 95 % RH
- temperature coefficient: ± 0.03 % / °C (0 °C to 60 °C)
- vibration: 10 to 500 Hz, 5 G 12 min. / 1 cycle, period for 72 min. each along X, Y, Z axes
- safety & EMC:
- safety standards: UL8750 (type "HL"), CSA C22.2 no. 250.13-12; ENEC EN61347-1, EN61347-2-13 independent, EN62384; GB19510.14,GB19510.1; IP65 approved
- withstand voltage: I/P-O/P: 3.75K VAC, I/P-FG: 2.0K VAC, O/P-FG: 1.5K VAC
- isolation resistance: I/P-O/P, I/P-FG, O/P-FG: 100M Ohm / 500 VDC / 25 °C / 70 % RH
- EMC emission: compliance to EN55015, EN61000-3-2 Class C (@load >/=50%); EN61000-3-3; GB17625.1,GB17743
- EMC immunity: compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV)
- others:
- MTBF: 978.2K hrs min.; Telcordia SR-332 (Bellcore) ; 282.9Khrs min.; MIL-HDBK-217F (25 °C)
- dimensions: 199 x 63 x 35.5 mm (L x W x H)
Documents:По ЗаказуЦена с НСО