CATALOG PRODUCTS

Print

 

  • AC-DC SINGLE OUTPUT LED DRIVER WITH PFC - 3 WIRE INPUT - ADJUST WITH POTMETER

    Product code:

    ELG-240-24B-3Y

    Description:

    Features:
    1. constant voltage + constant current mode output
    2. metal housing design
    3. : built-in active PFC function
    4. no load / standby power consumption <0.5W
    5. IP67 rating for indoor or outdoor installations
    6. 3-in-1 dimming function (0~10 VDC, 10 V PWM signal and resistance)
    7. typical lifetime > 50.000 hours
    8. 5 years warranty
    9. with build-in earth wire
    10. 3 in 1 dimming function (0 ~ 10 Vdc, 10 V PWM signal and resistance)
    11. for professional use only
    12. This device must be installed by a qualified person.
    Specifications:
    1. output:
      1. DC voltage: 24 V
      2. constant current region : 12 V to 24 V
      3. rated current: 10 A
      4. rated power: 240 W (200 VAC to 305 VAC), 180 W (100 VAC to 180 VAC)
      5. ripple & noise (max.): 200 mVp-p
      6. voltage adj. range: 22.4 V to 25.6 V
      7. current adj. range: 5 A to 10 A
      8. voltage tolerance: ± 2.0 %
      9. line regulation: ± 0.5 %
      10. load regulation: ± 0.5 %
      11. setup, rise time : 500 ms, 100 ms / 230 VAC, 1000 ms / 115 VAC
      12. hold-up time (typ.): 10 ms / 230 VAC, 10 ms / 115 VAC
    2. input:
      1. voltage range: 180-295 VAC 255-417 VDC
      2. frequency range: 47 to 63 Hz
      3. power factor: PF >/= 0.97 / 115 VAC, PF >/= 0.95 / 230 VAC, PF >/= 0.92 / 227 VAC at full load
      4. total harmonic distortion: THD < 20%
      5. efficiency (typ.): 92 %
      6. AC current: 2.2 A / 115 VAC, 1.5 A / 230 VAC, 1.2 A / 227 VAC
      7. inrush current (typ.): cold start 75 A / 230 VAC
      8. max. PSUs on 16A circuit braker: 4 units (circuit braker type B) / 6 units (circuit braker type C) at 230 VAC
      9. leakage current: < 0.75 mA / 277 VAC
    3. protection:
      1. overcurrent :
        1. 95 to 108 %
        2. protection type: constant current limiting, recovers automatically after fault condition is removed
      2. short-circuit: hiccup mode, recovers automatically after fault condition is removed
      3. overvoltage:
        1. 27 V to 34 V
        2. protection type: shut down output voltage, re-power on to recover
      4. overtemperature: shut down output voltage, re-power on to recover
    4. environment:
      1. working temperature: -40 °C to +70 °C
      2. working humidity: 20 to 95 % RH non-condensing
      3. storage temperature, humidity: -40 °C to +80 °C, 10 to 95 % RH
      4. temperature coefficient: ± 0.03 % / °C (0 °C to 50 °C)
      5. vibration: 10 to 500 Hz, 5 G 12 min. / 1 cycle, period for 72 min. each along X, Y, Z axes
    5. safety & EMC:
      1. safety standards: UL8750 (type "HL"), EN61347-1, EN61347-2-13 independent, IP65 or IP67 approved
      2. withstand voltage: I/P-O/P: 3.75K VAC, I/P-FG: 2.0K VAC, O/P-FG: 1.5K VAC
      3. isolation resistance: I/P-O/P, I/P-FG, O/P-FG: 100M Ohm / 500 VDC / 25 °C / 70 % RH
      4. EMC emission: compliance to EN55015, EN61000-3-2 Class C (@load >/=50%); EN61000-3-3;
      5. EMC immunity: compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, light industry level (surge immunity Line-Earth 6KV, Line-Line 4KV)
    6. others:
      1. MTBF: 826.7K hrs min.; Telcordia SR-332 (Bellcore) ; 200.8Khrs min.; MIL-HDBK-217F (25 °C)
      2. dimensions: 244 x 63 x 35.5 mm
      3. packing: 1.22 kg; 12 pcs / 15.2 kg / 0.72 CUFT
    7. input wiring type: 3-wire input for standard model
    Documents:
    On order

    Price (VAT included):

    132.11 €